8 LED Indicator Troubleshooting In normal operation the Power LED is steady green and the PassFail is green or red depending on the triggered inspection 1 Green Power Red Error 2 Green Pass Red Fail The iVu also indicates abnormal conditions as described below 81 Errors Problem Indicator Solution The PassFail LED is blinking green a number of times separated by an LED red blink and the sen sor repeats this pattern over and over This indi cates that no inspections are occurring Reboot the sensor The Power LED is lit steady red These type of er rors are reported in the System log and appear highlighted in red Do the following 1 Look in the System Log to see the error 2 Clear the LED that is go to the Main Menu Logs System Logs and press the Clear System Error button at the bottom of the screen a sensor reboot is not required 3 If the error occurs again you can try rebooting the sensor to see if that fix es the problem If the problem persists contact Banner customer support 82 Warnings Warnings are atypical conditions that the sensor detects and fixes Warning are highlighted in yellow in the System Log and can typically be ignored iVu Plus Users Manual 76 wwwbannerengineeringcom tel 7635443164 Online Only rev A