NOTE When running a Match inspection the sensor will look for any possible patterns to match anywhere within the Field of View d Click the Teach icon to teach the sensor this good reference part With Annotations Enabled the screen will highlight in green the pattern found 2 Set inspection parameters Adjust the Percent Match parameter NOTE When running a Match inspection with annotations enabled the sensor will hightlight in green any pattern matches that meet or exceed the value specified for Percent Match Patterns that are below the specified value for Percent Match down to approximately 20 or out of the Rota tion Range see below will be colored yellow 1 Using a bad part click the Manual Trigger icon in the lowerright of the screen to capture an image For this example one of the stored images is missing the letter N yet the sensor initially sees this as a good label 2 Go to Main Menu Inspection and click the Percent Match option 3 On the adjustment at the bottom of the screen adjust the slider and click the Manual Trigger button When adjusted correctly the annotations should turn yellow and the icon in the upperright of the screen shouid indicate fail iVu Plus Users Manual Online Only rev A wwwbannerengineeringcom tel 7635443164 59