2 Move the slider at the bottom of the screen to the to the desired area range In the Demo example the Area Range is adjusted so that each letter is identified as a found object indicated by the green hightlights and the blue Set the Pass Count parameter 1 Go to Main Menu Inspection and click the Pass Count option 2 Set the Minimum Pass Count and Maximum Pass Count as appropriate In the Demo both are set to 6 since the inspection should find six letters 6 Test the complete range of good and bad samples to make sure that the sensor accepts good parts and rejects bad 7 To complete the Area application setup set triggering as appropriate for your application NOTE Remote Teach does not work with the Area Sensor type 44 Configuring a Blemish Sensor This section describes how to configure a Blemish sensor using the Demo application as a reference The Demo application shows how the sensor when configured as a Blemish tool can accept or reject parts based on the range of edge pixels the sensor detects in the ROI Start the setup with a good part Normally each part to be tested will be centered in the Field of View FOV iVu Plus Users Manual Online Only rev A wwwbannerengineeringcom tel 7635443164 55