a Use the supplied 116 hex key to loosen the Focusing Window locking screw D then adjust focus on the iVu Series sensor using the clear Focusing Window B A Lens B Focusing Window C Locking Clip D Locking Screw E Filter Cap optional F Filter optional NOTE Filter Kits are avail able separate ly b Adjust focus while monitoring the focus number To ensure the best image adjust the focus until the Focus Number peaks NOTE Turning the Focusing Window counterclockwise focuses on closer objects while turning the Focusing Window clockwise focuses on more distant objects c Once the best image has been acquired lock the focusing window 43 Configuring an Area Sensor This section describes how to configure an Area sensor using the Demo application as a reference NOTE By default the Trigger is set to Internal and will continously trigger based on a time interval setting This may make it more difficult to make adjustments while setting up the sensor The best practice is as fol lows Go to the Main Menu Imager Trigger menu and select External iVu Plus Users Manual 52 wwwbannerengineeringcom tel 7635443164 Online Only rev A