Main Menu System Discrete IO Output Type Select NPN to configure the sensors outputs to sink current Select PNP to configure the sensors output for source current LCD Timeout Screen Main Menu System Display Settings LCD Timeout The LCD screen dims after a userselectable period when it is not being used Use the arrow keys or slide the bar at the bottom of the screen to set the LCD screen time out Lock Sensor Main Menu System Lock Sensor This option provides for locking the sensor to prevent accidental modification of settings When locked the sensor only provides access to passfail statistics as well as the ability to view logs and to save them to a USB device A lock icon in the upper left corner of the sensor display indicates that the sensor is locked Note that the sensor can be locked with or without a password If a password is not used unlock the sensor by clicking on the Unlock Device menu When a password is used it must be 4 digits entered using the software keypad If the password is lost use the Password Reset Utility software provi ded in the CD to obtain a Reset Key Output1 Screen Main Menu System Discrete IO Output1 Output1 can be configured for Pass Fail or Sort Pattern 1 The default setting is Pass and Latched for this output For Latched the signal is active until the results of an inspection cause a change in the signal output If Pulse is selected the default Pulse width is 50 ms Output2 Screen Main Menu System Discrete IO Output2 Output2 can be configured for Pass Fail or Sort Pattern 2 The default setting is Pass and Latched for this output For Latched the signal is active until the results of an inspection cause a change in the signal output If Pulse is selected the default Pulse width is 50 ms iVu Plus Users Manual 42 wwwbannerengineeringcom tel 7635443164 Online Only rev A