Ethernet IO Status Main Menu System Communications Ethernet IO Status The Ethernet IO Status screen can be used to verify that the Ethernet wiring has been correctly set up In addition to deter mining if link has been established incoming and outgoing traffic can be monitored Data Export Advanced Screen Main Menu System Communications Data Export Advanced During the Data and Image export operation the sensors output channels might become full This can occur if the sensor is producing export data frames faster than the data can be exported from the device due to bandwidth limitations or faster than the client is reading the channel export data This setting affects how the sensor will behave in this situation Select Hold READY to ensure that all frames are transmitted In this case the READY signal will remain inactive sensor is busy until the new frame has been added to the channel for transmission Triggers might be missed during this time Select Do not hold READY to cause the sensor to discard the new frame if the channel is full and thus activate the READY signal iVu Plus Users Manual Online Only rev A wwwbannerengineeringcom tel 7635443164 39