91 ltlutilit y supply c om GROUNDING JUMPERS TRUSTED SINCE 1958 Univ ersal Clamp C an be installed on all elec trical facilities apparatus tubes and c onduc t ors as w ell as various equipment trucks pulling equipment et c T his univ ersal clamp can also be used on a jumper cable I nstallation on c onduc t o r r ound bus bar and g r ounding ball stud of 25mm T hermal shock indicat or changes c olour fr om whit e t o r ed when the clamp r eaches a t emperatur e of 200 F 93C Str essr elief t o r educ e cable damage and ser v e as a shock damper if fault oc curs which pr ot ec ts cable strands L ocations on each side of the clamp f or 20mm or 25mm g r ounding ball studs installation which ser v e as suppor t studs f or either a g r ounding clust er or cascade assembly F itt ed t o r e c eiv e a 5811UNC thr eaded stud f e rrule L ubrication chamber f or upkeep of thr eads I nstallation ey e f or installing clamp with shot gun stick Double int e rnal thr eads f or fast installation and r emo val M a t e rial Aluminum Clamp and Keeper Br onz e or Aluminum E y e S c r e w Clamps Capacity 15 C y cles Capacity 30 C y cles F or Ground S tud Jumper Cable Min Jumper Cable Max Main Conduc t or Min in Main Conduc t or Max in Ja w C ontinuous Current Ra ting W eight lb 35kA IEC 43K A ASTM 30A ASTM 20mm 2 A W G 40 A W G 8 16 556 86 138 400A 13 35A IEC 55 kA ASTM 39kA ASTM 25mm 2 A W G 40 A W G 8 16 795 113 138 400A 14 Univ ersal Clamp D imension Capacity 15 C y cles Jumper Cable Min Jumper Cable Max Main Conduc t or Max in Main Conduc t or Max in F or Ground S tud Ja w T est ed 15 C y cles Max P eak L ast C y cle P eak W eight lb S tandard P ack 155 x 65 x 325 55kA IEC 74kA ASTM 2 40 10 40 1796 160 30mm 2 55kA IEC 47kA ASTM 126kA 70kA 39 6 155 x 65 x 325 55kA IEC 47kA ASTM 2 350 MCM 10 40 30mm 2 5kA IEC 68k 183kA 101kA 39 8 C an be installed on all elec trical facilities apparatus tubes and c onduc t ors as w ell as various equipment trucks pulling equipment et c I nstallation on c onduc t o r r ound bus bar and g r ounding ball stud of 30 mm T est ed t o 5H HC10041 and 7H HC10041A T est ed and c e r tif ed only with MPS c omponents Str ess r elief t o r educ e cable damage and ser v e as a shock damper if fault oc curs which pr ot ec ts cable strands F itt ed t o r e c eiv e a 5811 or 3410 UNC thr eaded stud f e rrule L ubrication chamber f or upkeep of thr eads Double int e rnal thr eads f or fast installation and r emo val No exposed thr eads f or minimal maint enanc e Body and E y e S c r e w Aluminum A356T6 A sk about L T L s 350 and 500 MCM grounding c ables and f errules f or large ampacity applic a tions ref er t o P age 14