CONSTRUCTION Conductors Flexible strand tin copper ASTM B172 and ICEA S75381NEMA WC58 Separator T ape separator between conductor and insulation Insulation Ethylenepropylene rubber EPR ICEA S75381 sec 315 table 316 Assembly Conductors and rubber fillers cabled to form round core Reinforcement Single faced rubber filled binder tape over insulation Jacket Black heavy duty CPE thermoset compound ICEA S75381 sec 34 table 34 Color Code ICEA S75381 sec 318 black white red green orange APPROV ALS UL E207132 Oil Resistant Oil Resistant Inners Sunlight Resistant 90C W et or Dry CUL E207132 FT1 FT5 40C 90C MSHA P7K268101 SPECIAL F ACT OR Y OPTIONS Jacket Other colors available MSHA P7K268077 Neoprene CSA 1523058 LR 103932 FT1 FT5 90C 40C Neoprene FEA TURES APPLICA TIONS Excellent fexibility W ater resistant and fame resistant Rated and fexible at 40C to 90C Excellent impact and abrasion resistant Ozone sunlight oil grease weather chemical resistant Portable power system s Other industrial applica tions Mining application where bare grounding conductors are not required Portable Power Cable 90C UL CUL MSHA Industrial Grade SPECIFICA TIONS ST ANDARDS ICEA S75381NEMA WC58 ICEA S95658NEMA WC70 ASTM B172 ASTM B 33 UL 44 2000V W Part Number Power Conductor Size Power Conductor Stranding Nominal Insulation Thickness Nominal OD Approx W eight Ampacity 1 30 C Ambient T emp A WG or MCM No of Stranding inches mm inches mm Ibs1000 ft kgskm A W85 W65 W45 W25 W15 W105 W205 W305 W405 8 A WG 6 A WG 4 A WG 2 A WG 1 A WG 10 A WG 20 A WG 30 A WG 40 A WG 133 7x19 259 7x37 259 7x37 259 7x37 259 7x37 266 19x14 342 19x18 418 19x22 532 19x28 006 006 006 006 006 008 008 008 008 152 152 152 152 152 203 203 203 203 107 124 136 156 185 198 213 227 246 272 315 352 398 471 504 541 576 626 776 1024 1432 2051 2665 3406 3596 4728 5512 1 154 1524 2131 3052 3967 5069 5351 7035 8203 52 69 91 121 141 164 189 219 252 Part Number Power Conductor Size Power Conductor Stranding Nominal Insulation Thickness Nominal OD Approx W eight Ampacity 1 30 C Ambient T emp A WG or MCM No of Stranding inches mm inches mm Ibs1000 ft kgskm A W66 6 A WG 259 7x37 006 152 130 330 1272 1891 69 1 Ampacity Free air measured Based on continuous duty at 90C conductor temperature per 201 1 NEC T able 4005A2 ST ANDARD PRINT LEGEND TF CABLE SIZE TYPE W POR T ABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DR Y UL E207132 CUL FT1 FT5 40C P7K268101MSHA 5 CONDU CT OR 6 CONDU CT OR Issue 68 April 2014 phone 6304069000 www tfcablecom 5