SHDGC 8000V 15000V CONSTRUCTION Conductors Flexible strand tinned copper ASTM B 172 and ASTM B33 C222 No 9609 sec 531 table 3 Conductor Shield Extruded semiconducting layer over conductor C222 No 9609 Insulation Ethylenepropylene rubber EPR C222 No 9609 sec 534 table 2 4 Insulation Shield Semiconduc ting bedding tape and composite tinned copperpolyamide braid 60 minimum coverage Color Code Polyamide braid color code black red blue C222 No 9609 table 1 Grounding Cond T inned copper C222 No 9609 sec 532 Ground Check Y ellow polypropyleneinsulated tinned copper conductor C222 No 9609 sec 533 table 4A Cable Assembly Three power conductors ground check and two noninsulated grounding conductors cabled together to form a round cable core Separator Single faced rubberfilled binder tape applied over core Jacket B l a c k e x t r a h e a v y d u t y h i g h t o r s i o n r e s i s t a n t i n t e g r a l f i l l e d reinforced Neoprene thermoset jacket C222 No 9609 sec 539 table 2 5 APPROV ALS CSA 1523058 LR 103932 FT1 FT5 40C 90C MSHA P07KA060012 SPECIAL F ACT OR Y OPTIONS Jacket Red yellow green orange blue MSHA P7K268101 CPE Jacket TPU Red yellow green orange blue MSHA P07KA030001 TPU Portable Power Cable Extra Heavy Duty EPR NEO 90C CSA MSHA Mining Grade SPECIFICA TIONS ST ANDARDS ICEA S75381NEMA WC58 ASTM B 172 ASTM B 33 CSA C222 No 9609 FEA TURES APPLICA TION Excellent fexibility Highly ozone sun weather water and fame resistant Rated and fexible at 40C Excellent impact and abrasion resistant Oil and heat resistant Indent printed for easy identifcation For use as trailing mining cables Use on AC of f track equipment such as longwall continuous miners loaders blast hole drillers conveyors pumps and mobile equipment requiring grounding conductors and ground check and metallic shielding overall For use in applications where ground check conductor is required for added safety Maximum continuous conductor temperature 90C ST ANDARD PRINT LEGEND TF CABLE VOL T AGE SIZE TYPE SHDGC CSA LR 103932 FT1 FT5 40C 90C P07KA060012MSHA 1 Ampacity Free air measured Based on continuous duty at 90C conductor temperature 2 Shortcircuit current 1s Based on conductor temperature from 90C up to 250C PowerGrounding Conductor Size Power Conductor Resistance at 25C Grounding Conductor Resistance at 25C Ground Check Conductor Resistance at 25C Inductance per unit length Operating Capacitance per unit length Permissible ShortCircuit Current 2 1s Ampacity 1 40C Ambient T emp Maximum Permissible T ensile Force A WG or MCM 1000Ft 1000Ft 1000Ft mH1000Ft F1000Ft kA A N 1 A WG 5 A WG 10 A WG 4 A WG 20 A WG 3 A WG 40 A WG 1 A WG 0137 0109 00868 00546 0349 0274 0227 0137 0679 01 17 01 13 0107 0101 009 010 01 1 013 606 765 964 1530 184 2 11 243 321 1900 2400 3000 4800 ELECTRICAL AND MECHANICAL P ARAMETERS Part Number Power Conductor Size Power Conductor Stranding Ground Check Conductor Size Grounding Conductor Nominal Insulation Thickness Nominal Jacket Thickness Nominal OD Approx W eight Size Stranding A WG or MCM N o o f Stranding AW G AW G No of Wires inches inches inches mm Ibs1000 ft kgskm SHDGC8KV13CSA SHDGC8KV103CSA SHDGC8KV203CSA 1 A WG 10 A WG 20 A WG 259 7x37 266 19 x14 342 19 x18 8 6 5 4 133 7x19 259 7x37 259 7x37 0150 0220 0220 0235 221 232 246 560 589 625 3300 3530 4160 491 1 51 12 6191 SHDGC15KV403CSA 40 A WG 532 19x28 8 2 259 7x37 0210 0265 305 775 6821 10151 20 www tfcablecom phone 6304069000 Issue 68 April 2014