8000V 15000V SHDGC CONSTRUCTION Conductors Flexible strand tinned copper conductor ASTM B172 and ICEA S75381 table 322 Conductor Shield Extruded semiconducting layer over conductor ICEA S75381 sec 314 Insulation Ethylenepropylene rubber EPR ICEA S75381 table 322 Insulation Shield Semiconduc ting bedding tape and composite tinned copperpolyamide braid 60 minimum coverage Color Code Polyamide braid color code black white red ICEA S75381 Grounding Cond T inned copper ICEA S75381 T ab 325 Ground Check Y ellow polypropyleneinsulated tinned copper conductor ICEA S75381 T ab 322 Cable Assembly Three power conductors ground check and two noninsulated grounding conductors cabled together to form a round cable core Separator Single faced rubberfilled binder tape applied over core Jacket Black extra heavy duty high torsionresistant integralfilled reinforced Neoprene thermoset jacket ICEA S75381 T ab 33 322 Sec 321 APPROV ALS MSHA P07KA0600121 SPECIAL F ACT OR Y OPTIONS Jacket Red yellow green orange blue MSHA P7K268101 CPE Jacket TPU Red yellow green orange blue MSHA P07KA030001 TPU Portable Power Cable Extra Heavy Duty EPR NEO 90C MSHA Mining Grade SPECIFICA TIONS ST ANDARDS ICEA S75381NEMA WC58 ASTM B 172 ASTM B 33 FEA TURES APPLICA TION Excellent fexibility Highly ozone sun weather water and fame resistant Rated and fexible at 40C Excellent impact and abrasion resistant Oil and heat resistant Indent printed for easy identifcation For use as trailing mining cables Use on AC of f track equipment such as longwall continuous miners loaders blast hole drillers conveyors pumps and mobile equipment requiring grounding conductors and ground check and metallic shielding overall For use in applications where ground check conductor is required for added safety Maximum continuous conductor temperature 90C ST ANDARD PRINT LEGEND TF CABLE VOL T AGE SIZE TYPE SHDGC FT1 FT5 40C 90C P07KA060012MSHA 1 Ampacity Free air measured Based on continuous duty at 90C conductor temperature 2 Shortcircuit current 1s Based on conductor temperature from 90C up to 250C PowerGrounding Conductor Size Power Conductor Resistance at 25C Grounding Conductor Resistance at 25C Ground Check Conductor Resistance at 25C Inductance per unit length Operating Capacitance per unit length Permissible ShortCircuit Current 2 1s Ampacity 1 40C Ambient T emp Maximum Permissible T ensile Force A WG or MCM 1000Ft 1000Ft 1000Ft mH1000Ft F1000Ft kA A N 2 A WG 6 A WG 10 A WG 4 A WG 20 A WG 3 A WG 40 A WG 1 A WG 0172 0109 00868 00546 0436 0274 0227 0137 0679 0122 01 13 0107 0101 009 010 01 1 013 480 765 964 1530 159 2 11 243 321 1500 2400 3000 4800 ELECTRICAL AND MECHANICAL P ARAMETERS Part Number Power Conductor Size Power Conductor Stranding Ground Check Conductor Size Grounding Conductor Nominal Insulation Thickness Nominal Jacket Thickness Nominal OD Approx W eight Size Stranding A WG or MCM N o o f Stranding AW G AW G No of Wires inches inches inches mm Ibs1000 ft kgskm SHDGC8KV103 SHDGC8KV203 SHDGC8KV403 10 A WG 20 A WG 40 A WG 266 19 x14 342 19 x18 532 19 x28 8 4 3 1 259 7x37 259 7x37 259 7x37 0150 0150 0150 0220 0235 0250 232 246 275 589 625 699 3530 4160 5590 51 12 6191 8319 SHDGC15KV23 SHDGC15KV103 SHDGC15KV203 SHDGC15KV403 2 A WG 10 A WG 20 A WG 40 A WG 259 7x37 266 19x14 342 19x18 532 19x28 8 6 4 3 1 133 7x19 259 7x37 259 7x37 259 7x37 0210 0210 0210 0210 0235 0250 0250 0265 241 264 273 305 612 671 693 775 3505 4614 4895 6821 5216 6867 7285 10151 Issue 68 April 2014 phone 6304069000 www tfcablecom 19