SHDGC 5000V CONSTRUCTION Conductors Flexible strand tinned copper ASTM B 172 and ASTM B33 C222 No 9609 sec 531 table 3 Conductor Shield Extruded semiconduc ting layer over conductor C222 No 9609 Insulation Ethylenepropylene rubber EPR C222 No 9609 sec 534 table 2 4 Insulation Shield Nonconductin g bedding tape and composite tinned copperpolyamide braid 60 minimum coverage Color Code Polyamide braid color code black red blue C222 No 9609 table 1 Grounding Cond T inned copper C222 No 9609 sec 532 Ground Check Y ellow polypropyleneinsu lated tinned copper conducto r C222 No 9609 sec 533 table 4A Cable Assembly Three power conductors ground check and two noninsulated grounding conductors cabled together to form a round cable core Separator Single faced rubberfilled binder tape applied over core Jacket Black extra heavy duty high torsionresistant integralfilled reinforced Neoprene thermoset jacket C222 No 9609 sec 539 table 2 5 APPROV ALS CSA 1523058 LR 103932 FT1 FT5 40C 90C MSHA P07KA060012 Portable Power Cable Extra Heavy Duty EPR NEO 90C CSA MSHA Mining Grade SPECIFICA TIONS ST ANDARDS ICEA S75381NEMA WC58 ASTM B 172 ASTM B 33 CSA C222 No 9609 FEA TURES APPLICA TION Excellent fexibility Highly ozone sun weather water and fame resistant Rated and fexible at 40C Excellent impact and abrasion resistant Oil and heat resistant Indent printed for easy identifcation For use as trailing mining cables Use on AC of f track equipment such as longwall continuous miners loaders blast hole drillers conveyors pumps and mobile equipment requiring grounding conductors and ground check and metallic shielding overall For use in applications where ground check conductor is required for added safety Maximum continuous conductor temperature 90C ST ANDARD PRINT LEGEND TF CABLE VOL T AGE SIZE TYPE SHDGC CSA LR 103932 FT1 FT5 40C 90C P07KA060012MSHA SPECIAL F ACT OR Y OPTIONS Jacket Red yellow green orange blue MSHA P7K268101 CPE Jacket TPU Red yellow green orange blue MSHA P07KA030001 TPU 1 Ampacity Free air measured Based on continuous duty at 90C conductor temperature 2 Shortcircuit current 1s Based on conductor temperature from 90C up to 250C 18 www tfcablecom phone 6304069000 Issue 68 April 2014 Part Number Power Conductor Size Power Conductor Stranding Ground Check Conductor Size Grounding Conductor Nominal Insulation Thickness Nominal Jacket Thickness Nominal OD Approx W eight Size Stranding A WG or MCM No of Stranding AW G AW G No of Wires inches inches inches mm Ibs1000 ft kgskm SHDGC5KV63 SHDGC5KV43 SHDGC5KV23 SHDGC5KV13 SHDGC5KV103 SHDGC5KV203 SHDGC5KV303 SHDGC5KV403 SHDGC5KV2503 SHDGC5KV3503 SHDGC5KV5003 6 A WG 4 A WG 2 A WG 1 A WG 10 A WG 20 A WG 30 A WG 40 A WG 250 MCM 350 MCM 500 MCM 133 7x 19 259 7x 37 259 7x 37 259 7x 37 266 19x14 342 19x18 418 19x22 532 19x28 627 19x33 888 37x24 1221 37x 33 8 8 8 8 8 8 8 8 6 6 6 10 9 7 6 5 4 3 2 1 10 30 49 7x7 133 7x19 133 7x19 133 7x19 259 7x37 259 7x37 259 7x37 259 7x37 266 19x14 342 19x18 532 19x28 01 10 01 10 01 10 01 10 01 10 01 10 01 10 01 10 0120 0120 0120 0185 0185 0205 0205 0220 0220 0235 0235 0250 0265 0280 156 168 187 195 208 220 236 250 269 295 331 396 427 475 495 528 559 599 635 683 749 841 1460 1769 2370 2660 3200 3615 4300 5059 6200 7700 10200 2173 2633 3527 3959 4762 5380 6398 7529 9227 1 1458 15178 PowerGrounding Conductor Size Power Conductor Resistance at 20C Grounding Conductor Resistance at 20C Ground Check Conductor Resistance at 20C Inductance per unit length Operating Capacitance per unit length Permissible ShortCircuit Current 2 1s Ampacity 1 40C Ambient T emp Maximum Permissible T ensile Force A WG or MCM 1000Ft 1000Ft 1000Ft mH1000Ft F1000Ft kA A N 6 A WG 10 A WG 4 A WG 8 A WG 2 A WG 6 A WG 1 A WG 5 A WG 10 A WG 4 A WG 20 A WG 3 A WG 30 A WG 2 A WG 40 A WG 1 A WG 250 MCM 10 A WG 350 MCM 20 A WG 500 MCM 40 A WG 0436 0274 0172 0137 0109 00868 00688 00546 00466 00333 00233 1109 0697 0436 0349 0274 0227 0172 0137 0109 00868 00546 0679 0679 0679 0679 0679 0679 0679 0679 0436 0436 0436 0132 01 19 01 12 0108 0105 0099 0098 0094 0089 0085 0082 008 009 010 01 1 012 014 014 016 018 021 024 190 303 480 606 765 964 1215 1530 1816 2531 3618 93 122 159 184 2 11 243 279 321 355 435 536 600 950 1500 1900 2400 3000 3800 4800 5800 7900 1 1400 ELECTRICAL AND MECHANICAL P ARAMETERS