CONSTRUCTION Conductors Flexible strand tin copper ASTM B 172 and C222 No 9603 table 9 Separator T ape separator between conductor and insulation C222 No 9603 sec 434 table 4 Insulation Ethylenepropylene rubber EPR C222 No 9603 table 1 1 Grounding cond T in copper C222 No 9603 sec 5143 and 5144 Ground check Y ellow polypropyleneinsulated tin copper conductor C222 No 9603 sec 514 Assembly Sizes 40 and smaller Three power ground check and two polyester green mylar t a p e d g r o u n d i n g c o n d u c t o r s c a b l e d t o g e t h e r Sizes 250 MCM and larger Three power ground check and two polyester green m y l a r t a p e d g r o u n d i n g c o n d u c t o r s c a b l e d t o g e t h e r t o f o r m round core Single faced rubber flled binder tape applied overall Reinforcement Nylon open braid applied overall Jacket Black extra heavy duty integralfilled CPE thermoset compound C222 No 9603 sec 511 12 and 4392 table 5 Color Code black blue red C222 No 9603 table 1 APPROV ALS UL E207132 Oil Resistant 90C W et or Dry Sunlight resistant Oil Resistant inners CUL E207132 FT1 FT5 40C 90C MSHA P7K268101 SPECIAL F ACT OR Y OPTIONS Jacket Other colors available MSHA P7K268077 Neoprene CSA 1523058 LR 103932 FT1 FT5 90C 40C Neoprene Jacket TPU Other colors available MSHA P07KA030001 TPU Portable Power Cable 90C UL CUL MSHA Mining Grade SPECIFICA TIONS ST ANDARDS CSA C222 No 9603 ICEA S75381NEMA WC58 ICEA S95658NEMA WC70 ASTM B 172 ASTM B 33 FEA TURES APPLICA TION Excellent fexibility Highly ozone sun weather and fame resistant Rated and fexible at 40C Excellent impact and abrasion resistant Special construction for reeling and trailing Oil and heat resistant Indent printed for easy identifcation For use as trailing mining cable Use on AC of f track equipment such as miners shuttle cars cutting machines loading machines and drills as well as conveyors and pumps Supply power to open pit strip and deep mines For applica tions requiring ground check conductor for added safety Part Number Power Conductor Size Power Conductor Stranding Size Nominal Insulation Thickness Nominal Jacket Thickness Nominal OD Approx W eight Ampacity 1 30 C Ambient T emp Ground Ground Check A WG or MCM No of Stranding AW G AW G inches inches inches mm Ibs1000 ft kgskm A GGC83MNGCAN GGC63MNGCAN GGC43MNGCAN GGC23MNGCAN GGC13MNGCAN GGC103MNGCAN GGC203MNGCAN GGC303MNGCAN GGC403MNGCAN 8 A WG 6 A WG 4 A WG 2 A WG 1 A WG 10 A WG 20 A WG 30 A WG 40 A WG 133 7x19 133 7x19 259 7x37 259 7x37 259 7x37 266 19x14 342 19x18 418 19x22 532 19x28 10 10 8 7 6 5 4 2 2 10 10 10 8 8 8 8 8 8 0060 0060 0060 0060 0080 0080 0080 0080 0080 0134 0146 0146 0165 0170 0170 0190 0197 0205 097 105 119 134 151 165 175 189 204 246 267 302 340 384 419 445 480 518 636 785 1086 1461 1861 2256 2695 3203 3889 947 1 168 1617 2176 2772 3360 4014 4770 5791 65 87 11 4 152 177 205 237 274 316 1 Ampacity Free air measured Based on continuous duty at 90C conductor temperature per 201 1 NEC T able 4005A2 ST ANDARD PRINT LEGEND TF CABLE SIZE TYPE GGC POR T ABLE POWER CABLE 2000V 90C SUN RES OIL RES 90C WET OR DR Y UL E207132 CUL FT1 FT5 40C P7K268101MSHA 3 CONDU CT OR GGC 2000V 12 www tfcablecom phone 6304069000 Issue 68 April 2014