Part Number Power Conductor Size Power Conductor Stranding Conductor Diameter Nominal Insulation Thickness Nominal Jacket Thickness Nominal OD Approx W eight Ampacity at Ambient T emp 30 C A WG or MCM No of Stranding inches inches inches inches mm Ibs1000 ft kgskm A DLO262 DLO313 DLO373 DLO444 DLO535 DLO646 DLO777 DLO929 D L O 1111 262 MCM 313 MCM 373 MCM 444 MCM 535 MCM 646 MCM 777 MCM 929 MCM 1111 M C M 65024 77524 92524 1 10024 132524 160024 192524 230024 275024 0660 0725 0787 0870 0950 1040 1130 1208 1370 0095 0095 0095 0095 01 10 01 10 01 10 01 10 0125 0065 0065 0065 0065 0065 0065 0065 0065 0095 0921 0984 1055 1138 1244 1355 1433 1516 1791 234 251 268 289 316 339 364 385 455 1068 1258 1462 1726 2018 2416 2881 3455 4077 1589 1872 2176 2568 3046 3595 4287 5142 6067 471 5 11 590 656 731 815 905 1005 111 5 Based on single conductor in free air 30C ambient air temperature 90C conductor temperature per 2005 NEC T able 31017 ST ANDARD PRINT LEGEND TF CABLE SIZE 90C DLO 2KV P7K26808001MSHA E193954 UL RHW2 2KV VW 1 ST1 SUN RES CSA 205591 R W90 EPR 1000V 40C FT1 FT4 TC SR OIL RES SPECIAL F ACT OR Y OPTION INTER TEK HIGH T ORSION TESTED AND INSPECTED RHHRHW 2R W90DLO WIND 2000V CONSTRUCTION Nominal voltage RHHRHW 2 600V and 2000V R W 90 CSA 1kV DLO 2kV Conductors Flexible strand tin coated copper conductor B172 ASTM B33 Separator T ape separator between conductor and insulation Insulation Ethylenepropylene rubber EPR UL CSA ICEA AAR RP588 90C Jacket Black heavy duty thermoset CPE ICEA S95658 NEMA WC70 AAR RP586 Bending radius For fixed minimum 4xD for flexible minimum 6xD D diameter of cable APPROV ALS UL E193954 RHW 2 90C wet and dry VW 1 Sun Res for 10 and larger ST 1 FT 4 IEEE1202 for CT use CUL E193954 TYPE R W90 EPR 1000V FT1 CSA 1 101269 LL103932 205591 R W 90 90C FT1 FT4 40C for 10A WG and larger OIL RES T ray Cable Sun Res MSHA P726808001MSHA FEA TURES APPLICA TION UL listed RHHRHW 2 600 V and 2000V for black jacket Rated 2kV DLO 1kV R W90 90C dry 90C wet Ozone sunlight oil grease weather water chemical and abrasion resistant jacket Rated R W90TC T ray Cable for sizes 10 A WG and larger MSHAVW 1 SUN RES FOR CT USE for sizes 10 A WG and larger and for black jacket Limited Smoke LS ST1 in accordance with UL 1685 CSA listed R W90 R W90TC for black jacket 1kV Designed for uses requiring a flexible heavy duty power cables For portable or fixed installations Leads for motors generators batteries jumper cables Deep well Submersible Pump Cable For use in renewable energy applications Shipyard and railroad applications SPECIFICA TIONS ST ANDARDS UL 44 ICEA S95658NEMA WC70 UL 1685 IEEE1202 CSA C222 No 38 CSA C222 No 230 ASTM B 8 ASTM B 33 AAR RP588 RP586 Portable Power Cable 90C UL CSA MSHA Industrial Grade 2000V DL O RHHR HW2 R W9 0 RW9 0TC Issue 68 April 2014 phone 6304069000 www tfcablecom 9